5k wind turbine sells very fast in the domestic and oversea market. Yixing Naier Wind Power Technology Co., Ltd is proud of developing it. Our designers are extremely innovative and have a keen sense in this field, thus they make the product be the pioneer for its appearance. From design, manufacturing, to finished products, we perform each process in accordance with the international standard. The quality of the product is entirely guaranteed.
Our products have achieved an increasing sale and a wide popularity since launched. They sell well at a competitive price and enjoy a high rate of repurchases. There is no doubt that our products have good market prospects and will bring a lot of benefits to customers at home and abroad. It is a wise choice for customers to allocate their money into working with Naier for further development and increase in revenue.
Pricing self-discipline is the principle we hold fast to. We have a very strict quotation mechanism which takes into consideration of the actual production cost of different categories of different complexities plus gross profit rate based on strict financial & auditing models. Due to our lean cost control measures during each process, we provide the most competitive quote on Yixing Naier Wind Power Technology Co., Ltd for customers.
Our wind turbine output is three-phase AC.
Wind turbines are usually used in off-grid or on-grid systems.
Power your off-grid cabin or sailboat with ease using our small 100W vertical wind turbine. Harnessing even mild gusts, it generates clean, sustainable energy, ensuring you stay connected, powered up, and eco-friendly wherever you go.
With the improvement of people's awareness of environmental protection and the wide application of renewable energy, we believe that many friends have seen wind turbines during their travels. Today, let us tell you the more details about vertical axis wind turbines.
According to the principle of vertical axis wind turbine,The speed of the wind turbine increases rapidly,its power generation rising speed is correspondingly faster, and the power generation curve becomes full. Under the same power conditions, the rated wind speed of the vertical axis wind turbine is smaller than the horizontal axis wind turbine, and the vertical axis wind turbine generates a large amount of electricity when operating at low wind speed.
From the mechanical analysis, the higher power of the vertical axis wind turbine, the the longer of the blades, the longer the distance between the center point of the parallel rod and the center point of the generator shaft,the worse the wind resistance ability, therefore, the triangular vector method can make up for some of the above shortcomings.
In the structure, we use the design of straight blade and triangular double fulcrum for vertical axis wind turbines, and the main stress points are concentrated in the hub, which solves the problems of blade falling off, breaking and blade flying out. The blades of vertical axis wind turbine form a circle according to the same Angle difference, so the design purpose can reduce the pressure on the center support. In addition, a series of auxiliary equipment such as gear boxes, reduction boxes and transmission devices can be placed on the working platform relatively close to the ground, reducing the weight of the fan itself, reducing the construction and maintenance costs of the fan to a certain extent, and the vertical axis wind turbine can be used in building integration, which is conductive to urban construction. Therefore, the overall performance index is high.
If you are interested in vertical axis wind turbines or have any questions, you can leave messages or private messages in the background.
The correct use of wind turbines is crucial for their normal operation and reliability. The following are the precautions to be taken when using wind turbines:
1. If the motor is found to be working abnormally, shaking or making abnormal sounds, it should be stopped for inspection.
2. When the fan rotates at high speed, do not stand or perform other work on the direction of the rotation plane of the wind turbine to prevent the blades from flying out and injuring people.
3. The battery should be kept dry and clean, and metal objects should not be placed on the battery pack to prevent short circuits.
4. Do not place the negative grounding of the electrical box and the single matched reverse order together to avoid short circuits. Use the reverse power supply according to the reverse power supply manual.
5. The tightener of the stay wire will automatically loosen when encountering strong winds. After adjustment, it can be locked with iron wire. After each strong wind, check if the stay wire is loose and promptly eliminate any looseness. (Upright pole must be vertical)
6. Wind turbines should be wired separately and not mixed with other lines. It is recommended to use DC power for lighting, and AC power output from inverters can be used for household appliances. (The inverter and inverter output lines cannot be connected in parallel, and the inverter output line cannot be connected to the mains.)
7.When wiring the electrical box, first connect the battery and then connect the output line of the generator. When disassembling, first disassemble the output line of the generator and then disconnect the wiring of the battery pack
8.The shutdown switch of the electrical box is usually in the starting position, and is used for temporary shutdown when the battery is fully charged or in defense against severe storms. Only the wind wheel is slowly running and unplugged to the shutdown position, and the switch is not allowed to be unplugged when rotating at high speed.
Overall, the proper use of wind turbines is essential to ensure equipment safety, improve performance and extend service life. This is also a key measure to ensure the reliable operation and efficient generation of wind power systems.